Review



image intensifier  (Lambert Instruments BV)


Bioz Verified Symbol Lambert Instruments BV is a verified supplier
Bioz Manufacturer Symbol Lambert Instruments BV manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 95

    Structured Review

    Lambert Instruments BV image intensifier
    Image Intensifier, supplied by Lambert Instruments BV, used in various techniques. Bioz Stars score: 95/100, based on 207 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/image+intensifier/HiCATT/10__1016_slash_j__combustflame__2026__114792-81-6-8
    Average 95 stars, based on 207 article reviews
    image intensifier - by Bioz Stars, 2026-09
    95/100 stars

    Images

    Related Articles

    other:

    Article Title: High-frequency self-sustained oscillations of a hydrogen jet flame
    Article Snippet: This work investigates a high-frequency thermoacoustic instability in an atmospheric laboratory-scale combustion test rig.. The flame is stabilized by a single-jet burner operated with pure hydrogen at thermal powers between 60 and 120 kW.. A parametric study is performed by varying the equivalence ratio and bulk flow velocity.

    Article Title: Performance Enhancement of Ammonium Dinitramide (ADN)-based Thruster using Coaxial Dielectric Barrier Discharge
    Article Snippet: To enhance the performance of conventional ADN-based catalytic ignition thrusters, a plasma-assisted thruster was developed employing coaxial cylinder electrodes within a 1N-class thruster configuration.. Steady-state ignition tests conducted on the experimental bench, demonstrated high repeatability in an atmospheric environment.. High-speed imaging and proper orthogonal decomposition (POD) analysis revealed that plasma reduced the pulsation energy of the first mode from 84.96% to 75.21%, improving flame stability and concentrating the flame in the upstream part of the combustion chamber, without propagating toward the nozzle.

    Article Title: Characterizing lean blowout dynamics of DME/air premixed swirl flames in a gas turbine model combustor with and without confinement
    Article Snippet: This work investigates lean blowout (LBO) dynamics of dimethyl ether (DME)/air premixed swirl flames in a gas turbine model combustor with and without confinement.. CH* chemiluminescence imaging and 2 kHz high-speed OH* chemiluminescence imaging are performed to capture the swirl flame macrostructures.. Particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF) are used to visualize the flow fields and reaction zones, respectively.

    Article Title: Towards efficient/low emission NH3 swirl combustion under axially staged regime through oxygen enrichment
    Article Snippet: Aimed at controlling emissions and increasing efficiency in a gas turbine combustor, this work conducts the experimental and kinetic modelling investigation on oxygen-enriched ammonia swirl combustion under axially staged regime.. Combustion and emission characteristics of ammonia/oxygen/nitrogen mixtures are explored using direct flame imaging, planar laser-induced fluorescence, and Fourier Transform Infrared spectroscopy.. The results reveal that oxygen enrichment strengthens combustion intensity and flame stabilization, thus contributing to the expanded stability limit.

    Article Title: Experimental and numerical investigation on flashback of low-swirling hydrogen–air jet flames
    Article Snippet: The camera was coupled with an image intensifier (Lambert Hicatt 25D), operating with a 30 μs exposure time, and equipped with a 100mm ultraviolet lens (Sodern CERCO 2178) at f/2.8.

    Article Title: Lewis number effect in lean premixed <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:math> -air and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi mathvariant="normal">C</mml:mi><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn>4</mml:mn></mml:msub></mml:mrow></mml:math> -air flames during thermoacoustic instability in a low-swirl combustor
    Article Snippet: Judai Masugi ,1,* Takeshi Shoji ,2 Yoshihiro Nakazumi,1 Ryota Fujii,1 Takuya Tomidokoro,3 Shigeru Tachibana ,2 and Takeshi Yokomori4,† 1Keio University, Graduate School of Science and Technology, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama, Kanagawa 223–8522, Japan 2Japan Aerospace Exploration Agency, Aviation Technology Directorate, 7-44-1 Jindaiji Higashi-machi, Chofu, Tokyo 182–8522, Japan 3King Abdullah University of Science and Technology, CCRC, PSE Division, 4700 King Abdullah University of Science and Technology, Thuwal 23955–6900, Kingdom of Saudi Arabia 4Keio University, Department of Mechanical Engineering, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama, Kanagawa 223–8522, Japan

    Imaging:

    Article Title: Experimental investigation on the thermoacoustic instability of boron/ethanol nanofluid fuel spray swirling flames
    Article Snippet: .. The imaging part was consisted of two identical high-speed cameras (Photron Fastcam SA–X) equipped with an image intensifier (Lambert HiCATT, gate = 40 μs) and UV lens (Sodern CERCO, 50 mm, f/1.8), operating at a recording frequency of 10 kHz. ..



    Similar Products

    95
    Lambert Instruments BV image intensifier
    Image Intensifier, supplied by Lambert Instruments BV, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/image+intensifier/HiCATT/10__1016_slash_j__combustflame__2026__114792-81-6-8
    Average 95 stars, based on 1 article reviews
    image intensifier - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    86
    Philips Healthcare image intensifier
    Image Intensifier, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/image+intensifier/image+intensifier/pm42269443-318-6-8
    Average 86 stars, based on 1 article reviews
    image intensifier - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    86
    Princeton Instruments image intensified charge coupled cameras iccd
    Image Intensified Charge Coupled Cameras Iccd, supplied by Princeton Instruments, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/image+intensifier/acton+charge+coupled+device+intensified+spectrometer/10__1016_slash_j__combustflame__2025__114741-118-17-26
    Average 86 stars, based on 1 article reviews
    image intensified charge coupled cameras iccd - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    95
    Lambert Instruments BV high speed image intensifier
    High Speed Image Intensifier, supplied by Lambert Instruments BV, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/image+intensifier/HiCATT/10__3390_slash_aerospace12111019-110-14-17
    Average 95 stars, based on 1 article reviews
    high speed image intensifier - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    86
    Siemens Healthineers image intensifier
    Image Intensifier, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/image+intensifier/image+intensifier/pmc12621107-115-1-11
    Average 86 stars, based on 1 article reviews
    image intensifier - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    95
    Lambert Instruments BV hicatt lens coupled image intensifier with ultraviolet uv sensitive s20 photocathode
    Hicatt Lens Coupled Image Intensifier With Ultraviolet Uv Sensitive S20 Photocathode, supplied by Lambert Instruments BV, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/image+intensifier/HiCATT/10__1016_slash_j__jaecs__2025__100408-67-25-24
    Average 95 stars, based on 1 article reviews
    hicatt lens coupled image intensifier with ultraviolet uv sensitive s20 photocathode - by Bioz Stars, 2026-09
    95/100 stars
      Buy from Supplier

    86
    Siemens Healthineers c arm image intensifier
    C Arm Image Intensifier, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/image+intensifier/image+intensifier/pmc12444181-66-2-7
    Average 86 stars, based on 1 article reviews
    c arm image intensifier - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    90
    PHOTONIS Inc image intensifier cricket2
    The LumaCam with a schematic of the detection principle. Neutrons are incident on a scintillation screen. The scintillation light is reflected by a mirror, focused by a lens, magnified in an MCP image <t>intensifier</t> and finally captured by a Timepix3 ASIC.
    Image Intensifier Cricket2, supplied by PHOTONIS Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/image+intensifier/photonis+cricket2/pmc12254470-3-0-7
    Average 90 stars, based on 1 article reviews
    image intensifier cricket2 - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results


    The LumaCam with a schematic of the detection principle. Neutrons are incident on a scintillation screen. The scintillation light is reflected by a mirror, focused by a lens, magnified in an MCP image intensifier and finally captured by a Timepix3 ASIC.

    Journal: Scientific Reports

    Article Title: Advances in detection for neutron reflectometry with time-resolved imaging detectors

    doi: 10.1038/s41598-025-99927-4

    Figure Lengend Snippet: The LumaCam with a schematic of the detection principle. Neutrons are incident on a scintillation screen. The scintillation light is reflected by a mirror, focused by a lens, magnified in an MCP image intensifier and finally captured by a Timepix3 ASIC.

    Article Snippet: Image intensifier , Increases photon intensity , Photonis Cricket2 , P47 phosphor.

    Techniques: